Data error: Sequence output signal (Reference value 30)

The signal turns on if the data reading or rewriting process is not carried out successfully.
 Function
The signal turns on when the address or data values are incorrect, or when data values are
incorrect (outside specification values) when performing teaching.
When the teaching signal is turned off, the data error turns off.
 Parameter settings
If assigning data errors to the sequence output terminal, set a value (30) corresponding to the
output terminal function setting parameter.

Address error: Sequence output signal (Reference value 31)

The signal turns on if the positioning data number is out of the range.
 Function
The signal turns on when AD3 to AD0 are all off, and the auto startup (4) signal turns on when
PA2_41 (sequential start selection) is "0" (disable).
The signal turns OFF when starting (rewriting) with the correct positioning data No.
 Parameter
To assign the address error to a sequence output terminal, specify the corresponding value ("31")
to the output terminal function setting parameter.