CHAPTER 4 PARAMETER
PA2_56 Speed limit selection at torque control
No.
Speed limit selection at
56
torque control
Select the method of setting limitation on the speed under torque control.
If the setting is 0, the reference value of PA1_26 (maximum rotation speed) is the speed limit.
If the setting is 1, the speed limit value selected with input signal (CONT signal): multi-step speed
selection 1 [X1] to 3 [X3] combination is applied.
4
PA2_57 to 60 Torque limit settings
No.
57
Torque limit selection
58
Second torque limit
Deviation hold
59
selection at torque limit
60
Third torque limit
The enabled torque limit is described below.
4-84
Extended Function Setting Parameters
Name
0: Parameter
1: Multi-step speed selection, VREF
terminal voltage
Name
0: As per CONT signal torque limit
0/1
1:TREF
GYB: 0 [%] to 350 [%]
Other than GYB: 0 [%] to 300 [%]
0: No deviation hold
1: Deviation hold at second torque
limit
2: TREF
GYB: 0 [%] to 350 [%]
Other than GYB: 0 [%] to 300 [%]
Setting range
Setting range
Default
Change
value
0
Power
Default value
Change
0
Power
GYB: 350 [%]
Other than GYB:
Always
300 [%]
0
Power
GYB: 350 [%]
Other than GYB:
Always
300 [%]