6.1.2 Key
The sub mode is selected.
The value increases by one (+1).
The sub mode is selected.
The value decreases by one (-1).
To display five or more digits, switch the display alternately between the four higher order digits and
four lower order digits. (5-digit data with no symbol is displayed without switching the displayed
digits.)
To display nine or more digits, switch the display alternately between the four higher order digits,
four middle order digits, and four lower order digits. (9-digit data with no symbol is displayed by
switching between the five higher order digits and five lower order digits.)
6.1.3 Flashing Display
There are times when the keypad flashes.
The flashing status and meanings are shown in the following table.
Flashing interval
Duration
1 second cycle
Continuous
0.5 second cycle
3 seconds
Once every 2
Continuous
seconds
Twice every 2
Continuous
seconds
*
: If valid parameters changed after restarting the servo amplifier.
[]
[]
Status
Alarm occurring
Setting parameters
In sequence test mode
Restart notification
CHAPTER 6 KEYPAD
[SET/SHIFT]
The cursor digit shifts to the right
(SHIFT).
The mode or value settles (SET).
Press and hold for at least one
second to settle.
[MODE/ESC]
The mode is switched (MODE).
The mode is deselected (ESC).
Recovery method
Restart the servo amplifier or reset
the alarm.
-
Restart the servo amplifier or,
change PA2_89 to 0 and then restart.
*
Restart the servo amplifier.
6
4
6-3
Display