Starting Up Procedure - Fuji Electric Alpha7 VV User Manual

Hide thumbs Also See for Alpha7 VV:
Table of Contents

Advertisement

11.3 Starting Up Procedure

Follow the procedure below to start up the absolute position system.
Install the battery
[1]
Enter PA1_02
[2]
Turn the main power and
[3]
control power off then on again.
AL. d L1
Perform position preset
[4]
Perform homing
[5]
Execute regular operation
[6]
 If the encoder cable is disconnected due to transportation or device changes, repeat the procedure
from step [4].
CHAPTER 11 ABSOLUTE POSITION SYSTEM
Connect the battery to the encoder wiring
correctly as described in section 11.2.
Set PA1_02 (INC/ABS system) at 1 (ABS) or 2
(endless non-overflow ABS).
To make new parameters enabled, turn the power off
then on again.
An absolute data lost alarm (dL1) is caused when
the power is turned on first after the absolute
position system is established. Execute position
preset to remove the alarm.
To establish the coordinate system of the absolute
position system, execute regular homing.
After above steps [1] through [5] are finished, the absolute
position system is established. You can start regular
operation.
Starting Up Procedure