Output Signal (Do) Forced Output - Mitsubishi Electric MELSERVO-J4 Instruction Manual

Hide thumbs Also See for MELSERVO-J4:
Table of Contents

Advertisement

3. DISPLAY AND OPERATION SECTIONS

3.8 Output signal (DO) forced output

Output signals can be switched on/off forcibly independently of the servo status. This function can be used
for output signal wiring check, etc. This operation must be performed in the servo off state by turning off
SON (Servo-on).
Operation
The display screen at power-on. Using the "MODE" button, display the diagnostic screen.
POINT
When the servo system is used in a vertical lift application, turning on MBR
(Electromagnetic brake interlock) by the DO forced output after assigning it to
connector CN1 will release the electromagnetic brake, causing a drop. Take
drop preventive measures on the machine side.
CN1
CN1
CN1
CN1
CN1
CN1
14
13
33
48
22
25
Press the "UP" button three times.
Press the "SET" button for 2 s or more.
......
Switch on/off the signal below the lit segment.
Always lit
......
Indicates on/off of output signal. Definitions of
on/off are the same as those for the external I/O
signals. (Light on: on, light off: off)
CN1
CN1
CN1
23
24
49
Press the "MODE" button once.
......
The lit LED moves to the upper LED of CN1-24.
Press the "UP" button once.
......
CN1-24 switches on.
(Between CN1-24 and DOCOM are connected.)
Press the "DOWN" button once.
......
CN1-24 switches off.
Press the "SET" button for 2 s or more.
3 - 23