4. HOW TO USE THE POINT TABLE
a) When you specify 270.000 degrees to the position data, the servo motor rotates in the CCW
direction.
b) When you specify -90.000 degrees to the position data, the servo motor rotates in the CW
direction.
c) When you specify -360.000 degrees to the position data, the servo motor rotates in the CW
direction. (A)
When you specify 360.000 degrees or 0 degree to the position data, the servo motor rotates in
the CCW direction. (B)
Current
position
Current
position
Target position
(A)
Current position
4 - 8
Target
position
Target
position
(B)