4. HOW TO USE THE POINT TABLE
4.6.2 Detailed setting window
You can change position data range and unit with the detailed setting for the point table window. For the
position data range and unit of [Pr. PT01] setting, refer to section 4.2.2. To reflect the setting for the
corresponding parameter, click the "Update Project" button in the point table window.
(1) Command method selection (PT01 *CTY) a)
Select a positioning command method from the absolute position command method and incremental
value command method.
(2) Miscellaneous
(a) Feed length multiplication parameter setting STM (PT03 *FTY) b)
Select any feed length multiplication from 1/10/100/1000.
(b) Position data unit setting (PT01 *CTY) c)
Select any unit of position data from mm/inch/degree/pulse. While degree or pulse is selected,
setting of feed length multiplication will be disabled.
a)
b)
c)
4 - 72