7. PARAMETERS
No./
Setting
symbol/name
digit
PL18
Set an identification signal amplitude used in the minute position detection method.
IDLV
This parameter is enabled only when the magnetic pole detection is the minute
position detection method.
Magnetic pole
detection -
However, setting "0" will be 100% amplitude.
Minute
position
Setting range: 0 to 100
detection
method -
Identification
signal
amplitude

7.2.8 Option setting parameters ([Pr. Po_ _ ])

No./
Setting
symbol/name
digit
Po12
_ _ _ x For manufacturer setting
*OOP3
_ _ x _ M code output selection
Function
0: Disabled
selection O-3
1: Enabled
Selecting "1" in this digit will enable you to check outputs according to M codes (0 to
99) set with point tables by using output devices of the communication function.
_ x _ _ For manufacturer setting
x _ _ _

7.2.9 Positioning control parameters ([Pr. PT_ _ ])

No./
Setting
symbol/name
digit
PT01
_ _ _ x Positioning command method selection
*CTY
0: Absolute value command method
Command
1: Incremental value command method
mode
_ _ x _ For manufacturer setting
selection
_ x _ _ Position data unit
0: mm
1: inch
2: degree
3: pulse
x _ _ _ RS-422 communication - Previous model equivalent selection
0: Disabled (MR-J4 standard)
1: Enabled (equivalent to MR-J3-T)
2: Enabled (equivalent to MR-J2S-CP)
For the communication command of the RS-422 communication, the status display
and read/write commands of input/output devices can be used with the data Nos. and
bit assignment of the same as previous models.
When this digit is "1" or "2", MR Configurator2 cannot be used with the USB
communication.
PT02
_ _ _ x Follow-up of SON (Servo-on) off/EM2 (Forced stop 2) off with absolute value
command method in incremental system
*TOP1
0: Disabled (Home position is erased at servo-off or EM2 off.)
Function
selection T-1
1: Enabled (Home position is not erased even if servo-off, EM2 off, or alarm
_ _ x _ For manufacturer setting
_ x _ _
x _ _ _ Point table/program writing inhibit
0: Allow
1: Inhibit
occurrence which can be canceled with reset. The operation can be continued.)
Function
Function
Function
7 - 68
Initial
Control mode
value
CP CL PS
[unit]
0
[%]
Initial
Control mode
value
CP CL PS
[unit]
0h
0h
0h
0h
Initial
Control mode
value
CP CL PS
[unit]
0h
0h
0h
0h
0h
0h
0h
0h