7. PARAMETERS
No./
Setting
symbol/name
digit
PB45
Set the command notch filter.
CNHF
_ _ x x
Command notch filter setting frequency selection
Command
Refer to table 7.6 for the relation of setting values to frequency.
notch filter
_ x _ _ Notch depth selection
Refer to table 7.7 for details.
x _ _ _ For manufacturer setting
Setting
value
Setting
value
Table 7.6 Command notch filter setting frequency selection
Frequency [Hz]
00
Disabled
01
2250
02
1125
03
750
04
562
05
450
06
375
07
321
08
281
09
250
0A
225
0B
204
0C
187
0D
173
0E
160
0F
150
10
140
11
132
12
125
13
118
14
112
15
107
16
102
17
97
18
93
19
90
1A
86
1B
83
1C
80
1D
77
1E
75
1F
72
Table 7.7 Notch depth selection
Depth [dB]
0
-40.0
1
-24.1
2
-18.1
3
-14.5
4
-12.0
5
-10.1
6
-8.5
7
-7.2
Function
Setting
Frequency [Hz]
value
20
70
21
66
22
62
23
59
24
56
25
53
26
51
27
48
28
46
29
45
2A
43
2B
41
2C
40
2D
38
2E
37
2F
36
30
35.2
31
33.1
32
31.3
33
29.6
34
28.1
35
26.8
36
25.6
37
24.5
38
23.4
39
22.5
3A
21.6
3B
20.8
3C
20.1
3D
19.4
3E
18.8
3F
18.2
Setting
Depth [dB]
value
8
-6.0
9
-5.0
A
-4.1
B
-3.3
C
-2.5
D
-1.8
E
-1.2
F
-0.6
7 - 37
Initial
Control mode
value
CP CL PS
[unit]
00h
0h
0h
Setting
Frequency [Hz]
value
40
17.6
41
16.5
42
15.6
43
14.8
44
14.1
45
13.4
46
12.8
47
12.2
48
11.7
49
11.3
4A
10.8
4B
10.4
4C
10
4D
9.7
4E
9.4
4F
9.1
50
8.8
51
8.3
52
7.8
53
7.4
54
7.0
55
6.7
56
6.4
57
6.1
58
5.9
59
5.6
5A
5.4
5B
5.2
5C
5.0
5D
4.9
5E
4.7
5F
4.5