7. PARAMETERS
No./
Setting
symbol/name
digit
PT03
_ _ _ x Feed length multiplication [STM]
*FTY
0: × 1
1: × 10
Feeding
2: × 100
function
3: × 1000
selection
This digit will be disabled when [degree] or [pulse] of "Position data unit" is set in
[Pr. PT01].
_ _ x _ Manual pulse generator multiplication
0: × 1
1: × 10
2: × 100
_ x _ _ For manufacturer setting
x _ _ _
_ _ _ x Home position return method
PT04
0: Dog type (rear end detection, Z-phase reference)/torque limit changing dog type
*ZTY
1: Count type (front end detection, Z-phase reference) (Note)
Home
2: Data set type/torque limit changing data set type
position
3: Stopper type (Note)
return type
4: Home position ignorance (servo-on position as home position) (Note)
5: Dog type (rear end detection, rear end reference) (Note)
6: Count type (front end detection, front end reference) (Note)
7: Dog cradle type (Note)
8: Dog type (front end detection, Z-phase reference) (Note)
9: Dog type (front end detection, front end reference) (Note)
A: Dogless type (Z-phase reference) (Note)
Note. Setting "1" and "3" to "A" will trigger [AL. 37 Parameter error] for the indexer
_ _ x _ Home position return direction
0: Address increasing direction
1: Address decreasing direction d
Setting "2" or more to this digit will be recognized as "1: Address decreasing direction".
_ x _ _ Home position shift distance multiplication
Set a multiplication of [Pr. PT07 Home position shift distance].
0: × 1
1: × 10
2: × 100
3: × 1000
"0" to "3" can be used for the indexer method.
When [degree] of "Position data unit" is set in [Pr. PT01] in the point table method or
program method, "0" and "1" can be used. ("2" or more will be recognized as "1".)
x _ _ _ For manufacturer setting
PT05
Set a (linear) servo motor speed at home position return.
ZRF
Home
Setting range: 0 to permissible instantaneous speed
position
return speed
PT06
Set a creep speed after proximity dog at home position return.
CRF
Creep speed
Setting range: 0 to permissible instantaneous speed
method.
Function
7 - 69
Initial
Control mode
value
CP CL PS
[unit]
0h
0h
0h
0h
0h
1h
0h
0h
100
[r/min]/
[mm/s]
10
[r/min]/
[mm/s]

Hide quick links: