7. PARAMETERS
No./
Setting
symbol/name
digit
PT19
Set an address increasing side of the position range output address.
*LPPL
Upper and lower are a set. Set a range which POT (Position range) turns on with
[Pr. PT19] to [Pr. PT22].
Position
range output
address +
Setting address:
(third least
significant
digit)
PT20
*LPPH
Position
range output
Set a same sign for [Pr. PT19] and [Pr. PT20]. Setting a different sign will trigger
address +
[AL. 37 Parameter error].
(third most
When changing a setting, always set the third least significant digit before setting the
significant
third most significant digit.
digit)
The unit will be changed to 10
setting of [Pr. PT01].
Setting range: -999999 to 999999
PT21
Set an address decreasing side of the position range output address.
*LNPL
Upper and lower are a set. Set a range which POT (Position range) turns on with
[Pr. PT19] to [Pr. PT22].
Position
range output
address -
Setting address:
(third least
significant
digit)
PT22
*LNPH
Position
range output
Set a same sign for [Pr. PT21] and [Pr. PT22]. Setting a different sign will trigger
address -
[AL. 37 Parameter error].
(third most
When changing a setting, always set the third least significant digit before setting the
significant
third most significant digit.
digit)
The unit will be changed to 10
setting of [Pr. PT01].
Setting range: -999999 to 999999
PT23
Set an output time for when OUT1 (Program output 1) is turned on with the OUTON
command.
OUT1
Setting "0" will keep on-state. To turn it off, use the OUTOF command.
OUT1 output
setting time
Setting range: 0 to 20000
PT24
Set an output time for when OUT2 (Program output 2) is turned on with the OUTON
command.
OUT2
Setting "0" will keep on-state. To turn it off, use the OUTOF command.
OUT2 output
setting time
Setting range: 0 to 20000
PT25
Set an output time for when OUT3 (Program output 3) is turned on with the OUTON
command.
OUT3
Setting "0" will keep on-state. To turn it off, use the OUTOF command.
OUT3 output
setting time
Setting range: 0 to 20000
Function
Upper
Lower
3 digits
3 digits
[Pr. PT19]
[Pr. PT20]
STM
-(STM-4)
[μm], 10
Upper
Lower
3 digits
3 digits
[Pr. PT21]
[Pr. PT22]
STM
-(STM-4)
[μm], 10
7 - 72
-3
[inch], 10
[degree], or [pulse] with the
-3
[inch], 10
[degree], or [pulse] with the
Initial
Control mode
value
CP CL PS
[unit]
0
Refer to
Function
column
for unit.
0
Refer to
Function
column
for unit.
0
[ms]
0
[ms]
0
[ms]

Hide quick links: