Output Signal (Do) Forced Output - Mitsubishi Electric MELSERVO-J2-Super Series Instruction Manual

Servo amplifier
Hide thumbs Also See for MELSERVO-J2-Super Series:
Table of Contents

Advertisement

7. SERVO CONFIGURATION SOFTWARE

7.7.4 Output signal (DO) forced output

Each servo amplifier output signal is forcibly switched on/off independently of the output condition of the
output signal.
Click "Test" on the menu bar and click "Forced Output" on the menu.
Clicking displays the following window.
Since this window shows the precaution for use of the MR-J2S-B, click the "OK" button.
When the above choices are made, the following window appears:
(1) Signal ON/OFF setting ( a), b) )
Choose the signal name or pin number and click the "ON" or "OFF" button to write the corresponding
signal status to the servo amplifier.
(2) DO forced output window closing ( c) )
Click the "Close" button to cancel the DO forced output mode and close the window.
(3) Cancel of DO forced output
To cancel DO forced output, switch off the power of the servo amplifier.
a)
b)
c)