Mitsubishi Electric MELSERVO-J4 Instruction Manual page 317

Hide thumbs Also See for MELSERVO-J4:
Table of Contents

Advertisement

7. PARAMETERS
No./
Setting
symbol/name
digit
PD41
Select input devices to turn on them automatically.
*DIA3
_ _ _ x _ _ _ x (BIN): MD0 (operation mode selection 1)
Input signal
(HEX)
0: Disabled (Use for an external input signal.)
automatic on
1: Enabled (automatic on)
selection 3
_ _ x _ (BIN): MD1 (operation mode selection 2)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
_ _ x _ _ _ _ x (BIN): For manufacturer setting
(HEX)
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): OVR (Analog override selection)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): For manufacturer setting
_ x _ _ _ _ _ x (BIN): For manufacturer setting
(HEX)
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
x _ _ _ _ _ _ x (BIN): For manufacturer setting
(HEX)
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
Convert the setting value into hexadecimal as follows.
0 0
PD42
Select input devices to turn on them automatically.
*DIA4
_ _ _ x _ _ _ x (BIN): For manufacturer setting
Input signal
(HEX)
_ _ x _ (BIN): RT (Second acceleration/deceleration selection)
automatic on
0: Disabled (Use for an external input signal.)
selection 4
1: Enabled (automatic on)
_ x _ _ (BIN): RTCDP (Second acceleration/deceleration gain selection)
0: Disabled (Use for an external input signal.)
1: Enabled (automatic on)
x _ _ _ (BIN): For manufacturer setting
_ _ x _ _ _ _ x (BIN): For manufacturer setting
(HEX)
_ _ x _ (BIN): For manufacturer setting
_ x _ _ (BIN): For manufacturer setting
x _ _ _ (BIN): For manufacturer setting
Function
Signal name
MD0 (Operation mode selection 1)
MD1 (Operation mode selection 2)
Signal name
OVR (Analog override selection)
BIN 0: Use for an external input signal.
BIN 1: Automatic on
7 - 60
Initial
value
[unit]
0h
0h
0h
0h
Initial value
BIN HEX
0
0
0
0
0
Initial value
BIN HEX
0
0
0
0
0
0h
0h
Control mode
CP CL PS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j4-a-rj seriesMr-j4-a4-rj seriesMr-j4-a1-rj series

Table of Contents