2. SIGNALS AND WIRING
Device
Symbol
Next station No.
DI0
selection 1
Next station No.
DI1
selection 2
Next station No.
DI2
selection 3
Next station No.
DI3
selection 4
Next station No.
DI4
selection 5
Next station No.
DI5
selection 6
Next station No.
DI6
selection 7
Next station No.
DI7
selection 8
Second
RT
acceleration/dec
eleration
selection
Second
RTCDP
acceleration/dec
eleration gain
selection
Connector
pin No.
CN1-19
Indexer method
Select next station Nos. with DI0 to DI7.
A setting value at ST1 on will be enabled.
CN1-41
DI7
DI6
DI5
CN1-10
0
0
0
CN1-35
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
Note 1. 0: Off
1: On
2. [AL. 97.2 Next station position warning] will occur.
Turning on ST1 with RT-off will select acceleration/deceleration time
constants set with [Pr. PC01 Acceleration time constant 1] and [Pr. PC02
Deceleration time constant 1].
Turning on ST1 with RT-on will select acceleration/deceleration time
constants set with [Pr. PC30 Acceleration time constant 2] and [Pr. PC31
Deceleration time constant 2].
RT will not be accepted during operation.
Device (Note)
RT
0
1
Note. 0: Off
1: On
This has two functions of CDP (Gain switching) and RT (Second
acceleration/deceleration selection).
When RTCDP is off, the servo control gain set with [Pr. PB06], [Pr. PB08]
to [Pr. PB10] will be selected. Turning on ST1 (Forward rotation start) will
select acceleration/deceleration time constants set with [Pr. PC01
Acceleration time constant 1] and [Pr. PC02 Deceleration time constant 1].
When RTCDP is on, the servo control gain set with [Pr. PB29] to [Pr.
PB32] will be selected. Turning on ST1 (Forward rotation start) will select
acceleration/deceleration time constants set with [Pr. PC30 Acceleration
time constant 2] and [Pr. PC31 Deceleration time constant 2].
Function and application
Device (Note 1)
DI4
DI3
DI2
DI1
DI0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
1
1
1
1
1
1
1
1
1
Description
Acceleration time
constant
[Pr. PC01]
[Pr. PC30]
2 - 18
division
Selection contents
0
Next station No. 0
1
Next station No. 1
0
Next station No. 2
1
Next station No. 3
0
Next station No. 254
1
Setting inhibited
(Note 2)
Deceleration time
constant
[Pr. PC02]
[Pr. PC31]
Control
I/O
mode
CP CL PS
DI-1
DI-1
DI-1