4. HOW TO USE THE POINT TABLE
(3) Manual pulse generator multiplication
(a) Using the input signals (devices) for setting
In "Device setting" of MR Configurator2, set TP0 (Pulse generator multiplication 1) and TP1 (Pulse
generator multiplication 2) to input signals.
TP1 (Pulse generator
TP0 (Pulse generator
multiplication 2)
multiplication 1)
(Note)
0
0
1
1
Note. 0: Off
1: On
(b) Using the parameter for setting
Use [Pr. PT03] to set the servo motor rotation multiplication to the rotation amount of the manual
pulse generator.
[Pr. PT03] setting
_ _ 0 _
_ _ 1 _
_ _ 2 _
(4) Operation
Turning the manual pulse generator starts the servo motor rotation. For the rotation direction of the
servo motor, refer to (2) of this section. When you turn the manual pulse generator during a JOG
operation, the commands inputted from the manual pulse generator are adjusted by the commands of
JOG operation.
Servo motor rotation multiplication
to manual pulse generator rotation
(Note)
0
[Pr. PT03] setting valid
1
0
1
Servo motor rotation multiplication to manual pulse
generator rotation amount
1 time
10 times
100 times
[mm]
amount
1 time
0.001
10 times
0.01
100 times
0.1
[mm]
0.001
0.01
0.1
4 - 44
Travel distance
[inch]
[degree]
[pulse]
0.0001
0.001
1
0.001
0.01
10
0.01
0.1
100
Travel distance
[inch]
[degree]
[pulse]
0.0001
0.001
1
0.001
0.01
10
0.01
0.1
100