11. PARAMETER UNIT

11.1 External appearance and key explanations

The following shows the external appearance and how to set the keys.
Display
LCD screen (16 characters ×
4 lines) shows such as Parameter
settings, Monitors, etc.
Key
Monitor mode key
Displays the monitor screen.
Alarm/diagnosis mode key
Displays the alarm/output signal (DO) forced output/diagnosis selection
screen.
Parameter mode key
Displays parameter selection screen.
Pressing this key with pressing down the "SHIFT" key displays the
point table setting screen.
Test operation mode key
Displays the selection screen for the test operation mode.
Function key
Used to operate the test operation mode.
Displays the parameter range and point table setting range.
SHIFT key
When entering hexadecimal values, pressing the "4" to "9" keys with
pressing down this key will enter A to F.
Pressing the "
screen to the previous or next screen.
ESC key
Switches the screen to the upper hierarchy. (not to the previous screen)
Displays the setting selection screen (initial screen) in the monitor
mode, etc.
Scroll key
Moves the cursor across the screen or scrolls the screen. Pressing this
key with pressing down the "SHIFT" key will switch the screen to the
previous or next screen.
Changes the parameter No. or point table No.
Forward rotation key
Starts the forward rotation during the test operation (JOG operation/
positioning operation).
Symbol key/reverse rotation key
Starts the reverse rotation during the test operation (JOG operation/
positioning operation).
Used together with the "SHIFT" key to enter negative numbers.
To exit the negative number mode, press the "SHIFT" key with this
key again. ("-" disappears.)
Stop/reset key
Stops temporarily in the JOG operation/Positioning operation/
Single-step feed.
Used as the "RESET" key while the "Fn" key is not pressed
(i.e. at a stop).
Resets alarms or alarm history, or clears cumulated monitor data or
inputs.
This key is not for stopping normal operation.
Enter key
Determines the selection, numerical values.
Determines to exit the test operation mode.
Switches outputs on/off of the output signal (DO) forced output.
Numerical key
Enters numbers such as the parameter Nos., setting values.
Pressing the "4" to "9" keys with pressing down the "SHIFT" key will
to
enter A to F.
Decimal point key
Used to enter a decimal point.
Starts the single-step feed.
11 - 2
Key explanation
" keys with pressing down this key will switch the

Hide quick links: