2. SIGNALS AND WIRING
(2) OVR (Analog override selection)
Select enabled/disabled of VC (Analog override).
Select a changed value using OVR (Analog override selection).
(3) Analog override offset ([Pr. PC37])
You can set an offset voltage to the input voltage of VC (Analog override) with [Pr. PC37]. The setting
value is from -9999 to +9999 [mV].
OVR (Analog override selection)
VC (Analog override)
-10 V to +10 V
(Note) External input
signal
0
1
Note. 0: Off
1: On
Servo amplifier
Speed change value
No change
Setting of VC (Analog override) is
enabled.
2 - 28