7. PARAMETERS
No./
Setting
symbol/name
digit
PC19
_ _ _ x Encoder output pulse phase selection
*ENRS
Select an encoder pulse direction.
Encoder
0: Increasing A-phase 90° in CCW or positive direction
output pulse
1: Increasing A-phase 90° in CW or negative direction
selection
_ _ x _ Encoder output pulse setting selection
0: Output pulse setting
1: Division ratio setting
2: The same output pulse setting as command pulse
3: A-phase/B-phase pulse electronic gear setting
4: A/B-phase pulse through output setting
When you select "1", the settings of [Pr. PA16 Encoder output pulses 2] will be
disabled.
When you select "2", the settings of [Pr. PA15 Encoder output pulses] and [Pr. PA16
Encoder output pulses 2] will be disabled. Additionally, it will be the servo motor side
pulse unit for the indexer method. When you select the setting, do not change the
settings in [Pr. PA06] and [Pr. PA07] after the power-on.
Setting "4" will be enabled only when A/B/Z-phase differential output linear encoder is
used. And "Encoder output pulse phase selection (_ _ _ x)" will be disabled. When
another encoder is connected, [AL. 37 Parameter error] will occur. Setting "Standard
control mode (_ _ 0 _)" in [Pr. PA01] will trigger [AL. 37 Parameter error].
_ x _ _ Selection of the encoders for encoder output pulse
Select an encoder used the encoder output pulses which the servo amplifier outputs.
0: Servo motor encoder
1: Load-side encoder
This is only for the fully closed loop system.
If "1" is set other than in the fully closed loop system, [AL. 37 Parameter error] will
occur.
x _ _ _ For manufacturer setting
PC20
Specify a station No. of the servo amplifier for RS-422 and USB communication.
*SNO
Always set one station to one axis of the servo amplifier. Setting one station number to
two or more stations will disable a normal communication.
Station
No. setting
Setting range: 0 to 31
PC21
Select the details of RS-422 communication function.
*SOP
_ _ _ x For manufacturer setting
RS-422
_ _ x _ RS-422 communication baud rate selection
communicatio
When using the parameter unit, set "1 _ _ _" in [Pr. PF34].
n function
0: 9600 [bps]
selection
1: 19200 [bps]
2: 38400 [bps]
3: 57600 [bps]
4: 115200 [bps]
_ x _ _ RS-422 communication response delay time selection
0: Disabled
1: Enabled (responding after 800 μs or longer delay time)
x _ _ _ For manufacturer setting
Function
Servo motor rotation direction/linear servo motor
Setting
value
CCW or positive direction
A-phase
0
B-phase
A-phase
1
B-phase
7 - 45
travel direction
CW or negative direction
A-phase
B-phase
A-phase
B-phase
Initial
Control mode
value
CP CL PS
[unit]
0h
0h
0h
0h
0
[Station]
0h
0h
0h
0h