After entering the new values, Click Set Min/Max Width to
12
write the new values to the PLC. Then click Ok to start the
calibration.
During calibration the following message appears.
When calibration is finished, the conveyor will step 30 mm
off the sensors and then home.
The conveyor will home. Before homing the PLC will check if
the rail is on a sensor. If a sensor is triggered then the rail
will move out 50 mm and then commence homing.
When homing the adjustable rail moves in until it triggers the
Left Min sensor. It will then look for the Right Min sensor. If
it is not found the 'Right Motor Only' will be switched on and
adjusted inwards by up to 5 mm. Once the sensor is found,
the 'Right Motor Only' will be switched off, and both motors
will go to the minimum width position.
When homed the following is displayed:
If any errors are encountered during calibration or homing, an
error message will be displayed. Exit the AWA function and
reset the PLC from the switch plate before attempting the
calibration process again.
Auto Width Adjust Conveyor Setup
6
6-9