Agilent U1840A Medalist sj5000 Hardware Manual
b
On the Action tab of the Controller Summary window,
click the Reset button for Controller 0.
c
On the Config tab, make sure the Sample Rate is set to
8000. If it is not, the SJ5000.xmp file has to be
downloaded (follow the instructions in
Parameters to MEI Card and Drives"
On the MoCon toolbar, click the A button.
2
On the Axis tab, make sure both Axis 0, Controller 0 and Axis
a
1, Controller 0 appear in the Object List. If not, select them
11
Troubleshooting
"Download
to do so).
11-29