Automated optical inspection system
Table of Contents

Advertisement

Agilent U1840A Medalist sj5000 Hardware Manual
Click this:
Check that feedback shows this:
45c Ring
10FF@F*
The blue 45c degree ring should turn on and the 45b degree ring
turn off.
45d Ring
08FF@6*
The red 45d degree ring should turn on and the 45c degree ring
turn off.
The Terminal window should now show the following:
Click Level 3 to move to level 4.
15
In addition to having lighting rings (such as the 90 degree
ring), the lighting head is also divided into eight segments.
The segments contain four rings, which are tested in level 4.
16
Perform the following checks:
Click this:
Check that feedback shows this:
45a_d S1
7801@0*
A segment in the lighting head should turn on and the 45d
degree ring turn off.
45a_d S2
7802@1*
The next segment (in an anti-clockwise direction) should turn on
and the previous segment turn off. As you click the following
buttons, the segments should turn on (and off) in sequence.
45a_d S3
7804@3*
45a_d S4
7808@7*
45a_d S5
7810@0*
45a_d S6
7820@1*
Camera and Lighting Controller Testing