Agilent Technologies U1840A Medalist sj5000 Hardware Manual page 66

Automated optical inspection system
Table of Contents

Advertisement

6
Auto Width Adjust Conveyor Setup
6-4
1
Loosen the screws along the length of the finger clamp using
a 2 mm Allen key. Use care when loosening the screws as
they may be very tight. Remove the finger clamp.
Loosen all screws along the
length of the finger clamp
2
Measure the distance from the inside of the linear rail to the
outside of the black lip where the belt edge ends. When
setting the clearance to 3.5 mm, this distance should be
2.5 mm.
3
If necessary, loosen the screws along the linear rail. Use care
when loosening the screws as they may be very tight. It may
help to add a drop of oil or anti seizure solution. Adjust the
distance to 2.5 mm along the whole length of the conveyor.
4
When you are satisfied that the whole rail is set at the correct
distance, tighten all the screws along the linear rail.
5
Replace the finger clamp and ensure that it is aligned with
the board clamps.
6
Place the finger clamp back on top of the linear rail and then
align its front edge with the edge of the board clamps. Move
on top rail
2.5 mm distance set
along whole length
of rail