AWA Setup and Calibration

Auto Width Adjust Calibration
Agilent U1840A Medalist sj5000 Hardware Manual
Perform the following steps:
1
Set up the sensors and flags. Refer to
Setup"
for instructions. Also see
description of the sensors and flags.
2
Ensure that all sensors and I/O are working correctly:
Trigger each of the AWA sensors individually, using a small
screwdriver or piece of paper to simulate the sensor
triggering. You will need another person check the PLC
inputs on the control panel in the rear of the machine. Verify
that the PLC input LED turns on and off as you activate and
deactivate the sensor.
Input
Sensor
01.00
Left Max Sensor
01.01
Left Min Sensor
01.02
Right Min Sensor
1
Ensure there are no boards in the sj5000.
2
Launch the sj5000 software in Engineer mode.
From the Tools menu click the Auto Width Adjust folder.
3
Click Calibrate.
4
5
Open the front access door. Adjust the rails inwards until
they can no longer move. (The ball screw housing rubber
stops will not allow further movement.)
Auto Width Adjust Conveyor Setup
"AWA Mechanical
"Sensors and Flags"
6
for a
6-7