Switch Plate
The switch plate is located on the left side of the sj5000, behind
the monitor. A cable (p/n 5186-6312) is connected to the back
and fed to the control panel where it is terminated at XB5 (see
the Electrical Drawing document for details).
Figure 2-3
Switch plate
Table 2-1 Controls on the switch plate
Item
Description
START switch
The AC power control switch for the whole system
after the mains isolator and residual current circuit
beaker (RCCB).
RUN light
The ON indicator light for the START switch.
ES RESET button
Resets the safety relay after any E-Stop button is
pressed or the front access door is opened. Pull out all
E-Stop buttons and close the front access door before
resetting the E-Stop circuit.
RAIL 1 INSP/PASS
Activates the pass-through functionality on rail 1. This
switch
allows the board to pass through the sj5000 without
being inspected. The default setting is Insp.
RAIL 2 INSP/PASS
Does the same with the rail 2 conveyor. This is only
switch
present on a dual rail sj5000.
single rail machine with only one conveyor fitted.)
Introduction to the Medalist sj5000
(Figure 2-1
2
shows a
2-7