The Terminal window should now show the following:
Keep clicking the Level button at the bottom right, until
9
Level 1 appears.
Click SEG CURR and check that the feedback is as follows:
10
*4SS0500@M*5SS0500@M*6SS0500@M*7SS0500@M*
11
Type in the following:
4SS469
5SS469
6SS469
7SS469
Click Read and check that the feedback is as follows:
12
'RYSC@R1SC857,0,3757*@R2SC957,0,3757*@R3SC22257,0,37
57*@R4SC2457,469,3757*@R5SC2557,469,3757*@R6SC957,4
69,3757*@R7SC1757,469,3757@END*'
The most important feedback result is when the READ button is clicked.
If there is no value in the middle of the each ring, as shown in the
example 4000*@R6SC700,0,4000, then this ring is not segmented. If the
feedback is 4000*@R6SC700,500,4000, then the ring is segmented.