9
Downloading PLC Programs
Downloading Using a USB Cable
Figure 9-1
CX-Programmer version 6.1 window
9-2
If you are using a PC other than the one on the sj5000, it must
have CX-Programmer version 6.1 installed.
The download procedure is as follows:
1
Connect a USB cable between the PC and the USB port of the
PLC.
2
Launch CX-Programmer version 6.1.
Click File > Open to open c:\cpi\data\PLC\sj5000.cxt.
3
Click PLC > Online.
4
The color of the program pane will change from white to
gray. If this does not happen, check the cable.
Click PLC > Transfer > To PLC.
5