Changing Conveyor Direction

Agilent U1840A Medalist sj5000 Hardware Manual
To change the conveyor direction from a left-to-right
configuration to right-to-left configuration, the clamp plates
need to be dismantled and swapped. The following shows the
default left-to-right configuration for the clamps.
To change to a right-to-left configuration, follow these steps:
1
Remove 16 screws from the linear block and four screws
from the motor block as shown above. Then remove the
clamp plate.
2
Remove the other clamp plate in the same way.
3
Swap the clamp plates.
4
Place the stopper at the left side as shown.
5
Replace all the screws.
Auto Width Adjust Conveyor Setup