Agilent Technologies U1840A Medalist sj5000 Hardware Manual page 61

Automated optical inspection system
Table of Contents

Advertisement

Agilent U1840A Medalist sj5000 Hardware Manual
Table 5-1 Tools for Auto Width Adjust
Field/Function
Description
Current Width
Displays the current distance between the conveyor rails.
If the conveyor rails are moving, the message 'Axis
Moving' is displayed.
Required Width
Lets you specify the desired distance between the
conveyor rails. Specify a value between the minimum and
maximum widths.
Move
Click Move to move the conveyor rails to the specified
distance apart.
Stop
Click Stop to abort a move operation. The conveyor rails
will stop moving and the Current Width shows the current
distance between the rails.
The move operation is also aborted when an E-Stop button
is pressed.
Jog Out/Jog In
Click Jog Out/Jog In to jog the conveyor rails out or in.
Each click moves the rails by the selected pulse increment:
0.5 mm, 1 mm, or 10 mm.
Hold down the Jog Out/Jog In buttons for continuous
movement of the conveyor rails.
AWA PLX Control Select this option to enable automatic adjustment of the
conveyor width based on the width setting in the PLX file
for a board.
To set the width, insert the following line in the PLX file:
w <microns>
For example, w 125000 sets the width to 125000 microns
or 125 mm.
Home
Returns the conveyor rails to a known position and
ensures that they stay parallel.
This should be used if the machine has been switched off
for a while or if any work carried out inside the machine
has caused the moving conveyor rail position to change.
Calibrate
Calibrates the automatic width adjust functionality. This
will set the conveyor width and also align the conveyor
rails. See "Calibration".
Changing the Conveyor Rail Width
5
5-5

Advertisement

Table of Contents
loading

Table of Contents