Table 7-1 Functions in Lighting Controller window
Area
Buttons
Lighting
Application
Next
Previous
Log
Focus
Auto Calibration
Set Location
Auto Calibration
Calibrate on Location
Agilent U1840A Medalist sj5000 Hardware Manual
• Lighting intensity grid
Shows the mean, sigma and range gray-level values of the
lighting rings.
Table 7-1
describes the functions in the Lighting Controller
window.
Description
Lets you select the lighting mode. Click to toggle through the available
lighting modes.
Displays the next view.
Displays the previous view.
Records the brightness of each of the lighting rings in the intensity.log file.
Allows you focus the camera with the front access door open. An E-Stop
alarm window will be visible and a Focus Camera instruction window
displayed. Note that the system is in E-Stop and no power or control is
given to the gantry or conveyor belt motors.
Sets the location of the calibration plate (available as an option) used for
auto calibration.
Automatically calibrates the lighting. You must set the location of the
calibration plate first.
Automatically calibrate the system with the gray card. See
Location".
Camera and Lighting Calibration
See"Auto
Calibration".
7
"Calibration on
7-15