Agilent Technologies U1840A Medalist sj5000 Hardware Manual page 159

Automated optical inspection system
Table of Contents

Advertisement

Agilent U1840A Medalist sj5000 Hardware Manual
2
Go to the folder C:\cpi. Open the ASALRC file with Notepad
and check the content:
3
If the above is present, the parameters for the motion
controller card and both the X and Y axes have to be
downloaded manually.
4
Download the parameters as follows:
Select Start > All Programs > Accessories > Command Prompt.
a
Type the following at the command line and press Enter:
b
cd \cpi\data\mei\tools
and press Enter:
c
Type
reset
d
To download the parameters to the X axis, type the
following and press Enter:
cddriveconfig -download -node 0 -file c:\cpi\
data\mei\x.txt
11
Troubleshooting