6
Auto Width Adjust Conveyor Setup
N O T E
6-14
Do not move the gantry using the cables assembly.
8
Use the potentiometer at the bottom of the sensor to adjust
the light to dark trigger.
9
Repeat this procedure for the Exit sensor and the In-Position
sensor.
10
When finished, push a board over each sensor and check PLC
input from the control panel.
Input
Sensor
00.06
Entry Sensor Rail 1
00.07
In-Position Sensor Rail 1
00.08
Exit Sensor Rail 1
01.05
Entry Sensor Rail 2
01.06
In-Position Sensor Rail 2
01.07
Exit Sensor Rail 2