Agilent Technologies U1840A Medalist sj5000 Hardware Manual page 139

Automated optical inspection system
Table of Contents

Advertisement

Agilent U1840A Medalist sj5000 Hardware Manual
Solder joint false failures
Review and follow the recommended best practices (the
Algorithm Manual) to solve the problem. Beyond that, perform
the following procedures.
• For c-type and r-type devices, set Top Plane to 'true' to
reduce stray reflections from neighboring devices.
• If an s-type device is locating well and has joints well tuned,
teach the individual false failing joint as good (only
applicable if using JointMVC or JointSLA).
• When tuning an s-type device:
Make sure the lead length and location are correct
Shift the joint position (light blue box) away from the end
of the lead. The blue box should be positioned adjacent to
the lead end with minimal coverage of the actual lead.
Reduce the joint box length to make sure it does not
extend beyond the pad.
Reduce or enlarge the joint box width to cover the pad
width.
No image available when using ART station
The problem is the image size.
• Open the Config.txt file located in the c:\cpi\data folder and
look for the line Image_save 52 1000 1000000 –1 1.
Change 1000000 to 2000000. This will increase the image size
and solve the problem.
11
Troubleshooting
11-5

Advertisement

Table of Contents
loading

Table of Contents