Camera and Lighting Calibration
7-4
11
Loosen the lens locking clamp.
12
Turn the focus ring on the lens until the board and
component leads are sharply focused on the screen.
13
When you have a sharp image, clamp the lens and tighten all
screws associated with the camera.
Turn the MAINT. SWITCH back to the OFF position. This
14
automatically closes the Maintenance window.
15
Close the front access door and clear the E-Stop alarm.
Click Ok on the Focus menu to re-enable the gantry motors.
16
After the camera has been focused correctly, the system scaling
must be performed and the lighting calibration should be
updated (see
"Lighting
Figure 7-1
Focus ring on the camera lens
Calibration").