Auto Width Adjust Conveyor Setup
6-8
6
Move the rails outwards until the fixed and moving rails are
50 mm apart and parallel. This is the minimum width and
should be measured between the inside linear rail on the
fixed rail and inside the linear rail of the adjustable rail.
Ensure they are parallel by measuring the rail separation at
either end of the rails.
7
Adjust the rail outwards by hand until the Left Min sensor is
not triggered. Then adjust the rail inward by hand until the
Left Min sensor is triggered. Measure and take note of the
conveyor width.
8
Adjust the rail inwards by hand until the Right Min sensor is
triggered. Measure and take note of the conveyor width.
Make sure that the difference between the Left Min sensor
getting triggered and the Right Min sensor is approximately
1 mm. The closer it is to 1 mm, the faster the conveyor will
calibrate.
9
Now adjust the rails outwards by hand to 70 mm, making
sure the conveyor rails are parallel at either end.
10
Close the front access door and reset the E-Stop circuit.
11
Enter the measured values noted above for the Left Min
sensor (Left Sensor Width) and the minimum width. In
Maximum Width Position, enter 510 mm for a standard
single rail system and 216 mm for a standard dual rail
system.