Agilent Technologies U1840A Medalist sj5000 Hardware Manual page 171

Automated optical inspection system
Table of Contents

Advertisement

Agilent U1840A Medalist sj5000 Hardware Manual
3
First, remove Axis 1 from the control of MS0.
Under Motion Supervisors, click MS 0, Controller 0. then
a
click Axes.
Right-click Axis 1, Controller 0 and select Remove Axis From
b
List.
Click Yes to confirm the removal.
c
d
The Object Explorer will show that Axis 1, Controller 0 is
no longer under the control of MS0.
4
Now map Axis 1, Controller 0 to MS 1, Controller 0.
Select the axis and drag and drop it into MS 1, Controller 0.
a
Click Yes to confirm.
b
5
When this is completed, go to the Motor Summary window.
On the Config tab, click the Save to Flash buttons.
11
Troubleshooting
11-37

Advertisement

Table of Contents
loading