4
Starting Up the Medalist sj5000
Powering Up From the Mains Off Position
4-4
To power up the sj5000 from the mains off position, do the
following:
Ensure that the START key switch at the front of the machine
1
and the mains isolator are in the OFF position.
2
Ensure that the XY table is free to move over its entire
envelope before continuing. Remove any tools or equipment
that may hinder the table as it moves inside the enclosure.
3
Ensure that the rear access panel is locked in position and
turn the mains isolator to the ON position.
Ensure that the MAINT. SWITCH is in the O position (off).
4
5
Ensure that the front access door is closed.
Turn the START key switch to the ON position. Ensure that
6
the green RUN light is lit. If the RUN light is not lit, check the
input power.
7
Turn on the UPS (if installed) and turn on the monitor.
8
Ensure that all four of the E-Stop buttons are pulled out.
9
Turn on the PC.
Press the ES RESET button.
10
Agilent U1840A Medalist sj5000 Hardware Manual