Figure A-34 Sliding the heat-shrink tubing onto the bare crimping terminal
Step 3 Fix the OT terminal (B) onto the exposed conductor, ensuring that the OT terminal is in
sufficient contact with the insulation layer of the power cable (C), as shown in
After the conductor is fed into the OT terminal, the protruding section of conductor (or L2 in
Figure
Step 4 Crimp the joint parts of the bare crimping terminal and the conductor, as shown in
A-35.
Figure A-35 Crimping the joint parts of the bare crimping terminal and the conductor
Step 5 Slide the heat-shrink tubing (A) towards the connector until the tube covers the crimped part
and then heat the tube with a heat gun, as shown in
Issue 03 (2017-12-15)
NOTICE
A-34) must not exceed 2 mm.
NOTE
The shapes of crimped parts may vary with the crimping dies.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure
A-36.
A Appendix
Figure
A-34.