Huawei USG9500 Series Hardware Manual page 421

Hide thumbs Also See for USG9500 Series:
Table of Contents

Advertisement

HUAWEI USG9500 Series
Hardware Guide
The air filter does not have memory. All monitored information is saved on the MPU, which may be inserted,
removed, switched, or replaced at any time. Therefore, the monitoring cycle may differ from the set cycle.
However, this does not affect the monitoring function.
Tool
Before replacing an air filter, you need the following tools:
l
l
Procedure
Step 1 Check the location of the air filter to be replaced.
Before pulling out an air filter that is to be replaced, check its location, that is, the cabinet and
chassis where the air filter resides and then label the air filter.
Step 2 Put on the ESD wrist strap and connect the grounding terminal to the ESD jack on the rack.
Step 3 Remove the air filter from the air intake frame.
1.
2.
Step 4 Install a clean and dry air filter in the air intake frame.
1.
2.
Issue 03 (2017-12-15)
NOTE
ESD wrist strap or ESD gloves
Phillips screwdriver
The air filter is located behind the device. Loosen the captive screws on the panel on the
rear of the device, as shown in
Holding the panel of the air filter, slowly pull the air filter out until it leaves the chassis,
as shown in
Figure 3-53
Figure 3-53 Removing the air filter from the air intake frame on the USG9520
Insert the clean and dry air filter into the chassis, as shown in
Fasten the captive screws onto the panel of the air filter, as shown in
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure 3-53
(1).
(2).
3 Hardware Maintenance
Figure 3-54
(1).
Figure 3-54
(2).