Note the following points when applying for a license file:
l
l
Step 3 Save the current configuration.
Run the save command to save the current configuration.
Run the compare configuration command to compare the saved configuration file and the
current configuration file.
Step 4 Save the startup software package and configuration file on the to-be-replaced MPU to the
local PC.
1.
2.
3.
Step 5 Prepare a new MPU/SRU and check whether there is any bent pin in the connector.
Step 6 Check the location of the MPU/SRU to be replaced.
Before pulling out an MPU/SRU that is to be replaced, determine the location of the MPU/
SRU, that is, the cabinet, chassis, and slot where the MPU/SRU resides. The USG9500 have
two MPUs/SRUs.
l
l
l
Locate the MPU/SRU to be replaced in the chassis and label the MPU/SRU.
Step 7 Check whether the MPU/SRU to be replaced is the active MPU/SRU.
Run the display device command to check the slot number of the current MPU/SRU. If the
MPU/SRU to be replaced is the active one, you must run the slave switchover command on
the console interface to force the active/standby switchover. If the output is displayed as
follows on the console interface, the switchover is successful. Then run the display device
command to check the slot number of the MPU/SRU after the active/standby switchover. If
the MPU to be replaced is the standby MPU, these operations are unnecessary.
[sysname] standby switchover enable
[sysname] standby switchover
Caution!!! Confirm switch standby to active[Y/N]? y
Switching....................................
[sysname]
Step 8 Remove the cables from the MPU/SRU and label the cables.
Step 9 Power off the MPU/SRU to be replaced.
Issue 03 (2017-12-15)
To use the ESN of the MPU/SRU to apply for a license file, obtain the revocation code
of the license file. Then use the revocation code of the ESN to apply for the license file.
For details, see License Application Guide for Security Product on ESDP.
According to the License Application Guide for Security Product on ESDP, use the
registered account to access
Enterprise Network > Security > Firewall & VPN Gateway > NGFW Module.
If the ESN of the MPU/SRU to be replaced is not used to apply for a license file, you
need to reapply for a license file. For details, see Applying For a License File.
Run the ftp command to establish a connection with the remote FTP server, namely, the
local PC.
Run the put xxx.cc command to save the startup software package to the local PC.
Run the put vrpcfg.zip command to save the configuration file to the local PC.
The MPUs of the USG9520 reside in slots 4 and 5.
The SRUs of the USG9560 reside in slots 9 and 10.
The MPUs of the USG9580 reside in slots 17 and 18.