Step 5 Insert the new CF card into the CF card 2 slot the MPU/SRU and push it in the proper
position, as shown in
3-44
Figure 3-44 Inserting CF card 2
Step 6 Check whether the new CF card is working properly.
You can check the running status of the new CF card in the following ways:
l
l
l
<sysname> dir ?
/all
STRING<1-64>
cfcard2:
cfcard:
slave#cfcard2:
slave#cfcard:
<cr>
The preceding output also indicates that the new CF card has returned to the normal state. If
the new CF card does not work normally, contact a local Huawei office for technical support.
----End
Issue 03 (2017-12-15)
Figure 3-44
(2).
Check the CF ACT indicator (green) on the panel of the MPU/SRU. If it is steady on or
blinking, the new CF card is working normally.
Check the alarms. If the system does not generate any alarm related to the new MPU/
SRU, the CF card is working properly.
Run the dir command on the console interface to check whether the new CF card can be
displayed. If the new CF card is working normally, the following is displayed: