Huawei USG9500 Series Hardware Manual page 306

Hide thumbs Also See for USG9500 Series:
Table of Contents

Advertisement

HUAWEI USG9500 Series
Hardware Guide
Figure 2-43 Indicator status when the USG9560 is operating properly
Rear view of the device
FAN
----End
Result
Table 2-8 Indicators on the AC power chassis
Item
Operation
indicator
Protection
indicator
Fault
indicator
Issue 03 (2017-12-15)
Lifting Hazard.May result in injury or
equipment damage.
STATUS
FAN
STATUS
Insert or remobe the fan
Hazardous moving parts,keep fingers
Insert or remobe the fan
frame with both hands
and other body parts away.
frame with both hands
FAN/FFU-A
FAN/FFU-B
RUN
RUN
ALM
Green,steady on
ON
PEM
PEM
PEM
NEG(-)
RTN(+)
NEG(-)
RTN(+)
NEG(-)
RTN(+)
Diagram of partitioned Power supply in the Syatem
PEM
PEM
PEM
FAN A3
FAN B3
OFF
A1
A2
FFU A4 FFU B4
B1
A1 A2
B1 B2
PEM
RUN
ALM
RUN
ALM
RUN
ALM
ON
ON
ON
OFF
OFF
OFF
-48~-60V;8.60A
-48~-60V;8.60A
-48~-60V;8.60A
Color
Green
Yellow
Red
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Front view of the device
Lifting Hazard.May result in injury or
equipment damage.
Blinking green
1
2
STATUS
Hazardous moving parts,keep fingers
and other body parts away.
ALM
Red, off
PEM
NEG(-)
RTN(+)
RS485
PEM
B2
1
2
RUN
ALM
ON
OFF
-48~-60V;8.60A
Status Description
If the indicator is
steady green, the AC
power chassis is
running properly. If
the indicator is off, an
exception occurs.
If the indicator is off,
the AC power chassis
is running properly. If
the indicator is on, an
exception occurs.
If the indicator is off,
the AC power chassis
is running properly. If
the indicator is on, an
exception has
occurred.
2 Hardware Installation
3
4
9
11
10
5
6
SRUA
SFUI-200-C
SRUA
RUN
Green, blinking once every two seconds
ALM
Grey, off
ACT
Green, steady on (for active SRU)
Green, off (for standby SRU)
3
4
9
11
10
5
6
Possible Exception Causes
There is no main AC power
input, the AC input voltage is
higher or lower than the normal
range, or the AC power chassis
has no output.
A temperature alarm is
generated (if the temperature
exceeds 65°C, the AC power
chassis will be powered off), or
the AC power chassis is in the
dormant state (the indicator is
on and no alarm is generated).
The AC power chassis is
powered off due to over-voltage
or over-temperature, or fans are
faulty, or the AC power chassis
has no output due to its internal
faults.
7
8
7
8
294

Advertisement

Table of Contents
loading

This manual is also suitable for:

Usg9520Usg9560Usg9580V300r001V500r001

Table of Contents