Step 7 Connect the cables to the corresponding interfaces in the original sequence.
Step 8 Log in to the device and run the power on slotslot-id command to power on the LPU
backplane whose FPIC has been replaced.
Step 9 Check the running status of the new FPIC.
Check the running status of the new FPIC in the following ways:
l
l
l
Issue 03 (2017-12-15)
Figure 3-10 Inserting an FPIC into the LPU
Check the STATUS indicator on the panel of the FPIC. If it is on (green), the FPIC is
working normally.
Check the alarms. If the system does not generate any alarm related to the new FPIC, the
new FPIC is working normally.
Run the display device command on the console interface. If the LPUs in the
corresponding slots are working normally, the following is displayed:
<sysname> display device
USG9520's Device status:
Slot #
Type
Primary
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-
1
SPU
NA
2
LPU
NA
4
MPU
Master
5
MPU
Slave
6
CLK
Master
7
CLK
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Online
Register
Present
Registered
Present
Registered
Present
NA
Present
Registered
Present
Registered
Present
Registered
3 Hardware Maintenance
Status
Normal
Normal
Normal
Normal
Normal
Normal