Huawei USG9500 Series Hardware Manual page 275

Hide thumbs Also See for USG9500 Series:
Table of Contents

Advertisement

HUAWEI USG9500 Series
Hardware Guide
l
l
Procedure
Step 1 Turn on the circuit breakers of external DC power supplies A and B.
Step 2 Measure the input voltage of the device with a multimeter to ensure that the voltage falls
between -72 V DC and -38 V DC.
Step 3 Turn on the DC power switch of the device.
Step 4 Wait three minutes and then check the status of the indicators.
Figure 2-22
Table 2-4
Figure 2-22 Indicator status when the USG9580 is operating properly
Rear view of the device
FAN
CMU
----End
Issue 03 (2017-12-15)
The power cable and PGND cable are properly connected.
The power switch in the equipment room is easy to locate so that you can quickly power
off devices in case of any problems.
shows the indicator status of main parts when the device is operating properly.
describes all indicators.
NOTE
If not all power modules have eight inputs, the STATUS indicator of the fan module is steady red.
Lifting Hazard.May result in injury or
Lifting Hazard.May result in injury or
equipment damage.
equipment damage.
STATUS
FAN
STATUS
STATUS
Insert or remobe the fan
Insert or remobe the fan
Hazardous moving parts,keep fingers
Hazardous moving parts,keep fingers
frame with both hands
and other body parts away.
frame with both hands
and other body parts away.
FAN-A5/FFU-A7
FAN-B5/FFU-B7
PEM-A1
PEM-A2
PEM-B1
PEM-B2
PEM
PEM
PEM
PEM
Diagram of partitioned Power supply in the Syatem
NEG(-)
RTN(+)
NEG(-)
RTN(+)
NEG(-)
RTN(+)
NEG(-)
RTN(+)
1
2
3 17 18 4
5
6
7
FAN A5
FAN B5
FFU A7
FFU B7
A1 A2
B1 B2
19
20
21
22
A3 A4
B3 B4
RUN
ALM
RUN
ALM
RUN
ALM
RUN
ALM
PEM
FFU A8
FFU B8
ON
ON
ON
ON
FAN A6
FAN B6
8
9 10 11 12 13 14 15 16
OFF
OFF
OFF
OFF
FRONT
REAR
-48~-60V;8.60A
-48~-60V;8.60A
-48~-60V;8.60A
-48~-60V;8.60A
PEM
PEM
PEM
PEM
NEG(-)
RTN(+)
NEG(-)
RTN(+)
NEG(-)
RTN(+)
NEG(-)
RTN(+)
RS485-1
Green,steady on
RUN
ALM
RUN
ALM
RUN
ALM
RUN
ALM
ON
ON
ON
ON
OFF
OFF
OFF
OFF
RS485-2
-48~-60V;8.60A
-48~-60V;8.60A
-48~-60V;8.60A
-48~-60V;8.60A
PEM-A3
PEM-A4
PEM-B3
PEM-B4
OR
128-270KG(282-595LBS)
FAN-A5/FFU-A7
FAN-B5/FFU-B7
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Front view of the device
Blinking green
1
2
1
2
RUN
ALM
Red, off
8
9
RUN
ALM
ON
OFF
8
9
2 Hardware Installation
3
17
18
4
5
6
7
MPUB
MPUB
Green, blinking once every two seconds
RUN
ALM
Grey, off
ACT
Green, steady on (for active MPU)
3
17
18
4
5
6
7
Green, off (for standby MPU)
19
20
21
22
10
11
12
13
14
15
16
10
11
12
13
14
15
16
263

Advertisement

Table of Contents
loading

This manual is also suitable for:

Usg9520Usg9560Usg9580V300r001V500r001