Count timing of High-Precision IGBT Output (Normal) (Timer 7)
Count
clock
TM7EN
bit
Compare
register 1
Compare
register 2
IGBT
trigger
Binary
0000
counter
TM7IO output
(IGBT output)
(A)
(B)
TM8IO output
(IGBT output)
Figure:9.10.1 Count timing of High-Precision IGBT Output (Normal)
• (A) Once the IGBT trigger is input, the IGBT operation is valid at the next clock. After the IGBT operation
becomes valid, the IGBT output holds "Low" until the next count clock
• (B) While the IGBT trigger is valid and the binary counter counts up from "0x0000" to the TM7OC2 compare
match, the IGBT output is "High". (Only for the 1st cycle of counting, the output is "High" from
"0x0001".)
• (C) After the TM7OC2 compare match, the output changes to "Low". The binary counter continues counting
up until it is cleared by the TM7OC1 compare match.
• (D) When the binary is cleared, the IGBT output returns to "High".
• (E) When the IGBT trigger becomes invalid, the timer is initialized and the IGBT output is forced to be
"Low".
0001
0002
M-1
M
N
M
M+1
M+2
N-1
N
(C)
16-bit High-Precision IGBT Output (with Variable Period/Duty)
0000
0001
L-1
L
(D)
Chapter 9
16-bit Timer
0000
(E)
IX - 53