Triumph Tiger Explorer XR 2017 Service Manual page 664

Table of Contents

Advertisement

Tiger Explorer XR Series
Windscreen Motor Undercurrent/Overcurrent
Fault Code
C1024
C1025
Pinpoint Tests
Test
1
Check fuse integrity:
- Main fusebox, fuse 3 (PS3)
2
Check cable and terminal integrity:
- Chassis ECM pin A53
- Chassis ECM pin A41
- Chassis ECM pin B01
3
Check cable for short circuit:
- Chassis ECM pin A53 to ground
- Chassis ECM pin A41 to ground
4
Check cable continuity:
- Chassis ECM pin A53 to windscreen
pin 1
- chassis ECM pin A41 to windscreen
pin 2
- Main fusebox, fuse 3 (PS3) to
Chassis ECM pin B01
5
Reconnect harness, clear fault code
and run engine to verify fault cleared
Circuit Diagram
660 of 746
Possible Cause
Windscreen motor undercurrent
Windscreen motor overcurrent
Result
OK
Faulty
OK
Faulty
OK
Short circuit
OK
Open circuit
OK
Fault still present
Action
Disconnect chassis ECM and
proceed to pinpoint test 1:
Disconnect chassis ECM and
proceed to pinpoint test 2:
Action
Disconnect windscreen motor connector
and proceed to test 2
Replace fuse, proceed to test 5
Proceed to test 3
Rectify fault, proceed to test 5
Proceed to test 4
Locate and rectify wiring fault, proceed
to test 5
Proceed to test 5
Locate and rectify wiring fault, proceed
to test 5
Action complete - quit test
Contact Triumph service
ELECTRICAL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents