Replacing A 2.5-Inch Backplane; Preliminary Steps; Removing The 2.5-Inch Hdd/Ssd Bay Top Cover - Fujitsu PRIMERGY TX1330 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX1330 M4:
Table of Contents

Advertisement

Hard disk drives (HDD) / solid state drives (SSD)
7.4.9

Replacing a 2.5-inch backplane

Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver
7.4.9.1

Preliminary steps

"Locating the defective server" on page 51
Ê
"Shutting down the server" on page 53
Ê
"Disconnecting the power cord" on page 54
Ê
"Getting access to the component" on page 55
Ê
Ê Release all HDD/SSD modules and pull them out a few centimeters, see
section
"Removing 2.5-inch HDD/SSD modules" on page
V
CUATION!
The HDD modules need not to be removed completely. But if you
want to remove them nevertheless, check if all HDD modules are
uniquely identified so that you can reinsert them into their original
bays.
Ê Release all dummy modules and pull them out a few centimeters, see
section
"Removing a 3.5-inch HDD dummy module" on page 176
"Removing a system fan" on page 262
Ê
Ê If applicable,
"Removing the SAS expander board" on page 255
Ê Disconnect all cables from the defective SAS backplane.
7.4.9.2

Removing the 2.5-inch HDD/SSD bay top cover

I
The 2.5-inch HDD/SSD front cover does not need to be removed in order
to replace a 2.5-inch HDD/SSD SAS backplane. In the figures, the front
cover has been removed for illustration purposes only.
212
Upgrade and Maintenance Manual
Hardware: 10 minutes
207.
TX1330 M4

Advertisement

Table of Contents
loading