14.7.1.1 Preliminary steps

"Locating the defective server" on page 51
Ê
"Note on network settings recovery" on page 288
Ê
"Suspending BitLocker functionality" on page 97
Ê
"Shutting down the server" on page 53
Ê
"Disconnecting the power cord" on page 54
Ê
Ê Disconnect all external cables.
"Getting access to the component" on page 55
Ê
Ê Remove the system fan module, see section
module" on page 81
Ê If applicable, remove the SAS expander board, see section
SAS expander board" on page 255
Ê Remove the following components from the system board as shown in the
related sections:
– Heat sinks:
I
Leave the CPU on the defective board for now.
– Memory modules:
I
Ensure to take note of the memory modules' mounting positions
for reassembly.
– Expansion cards:
If applicable, disconnect the riser card.
"Removing expansion cards" on page 285
I
Ensure to take note of the controllers' mounting positions and
cable connections for reassembly.
– iRMC microSD card:
– If applicable, M.2 SSD, see section
page 406
– If applicable, Dual microSD 64 GB Enterprise, see section
the Dual microSD 64GB Enterprise" on page 412
TX1330 M4
"Removing the heat sink" on page 321
"Removing memory modules" on page 315
"Removing the iRMC microSD card" on page 399
Upgrade and Maintenance Manual
System board and components
"Removing the system fan
"Removing the M.2 SSD" on
"Removing the
"Removing