Replacing The Front Panel; Preliminary Steps - Fujitsu PRIMERGY TX1330 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX1330 M4:
Table of Contents

Advertisement

Front panel
13.1

Replacing the front panel

Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver (for removing the rack front cover)
Other procedures: tool-less
Note on system information backup/restore
The front panel (front panel module, front panel board or front panel on QRL)
contains the Chassis ID EPROM that contains system information like server
name and model, housing type, serial number and manufacturing data.
To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored from
the system board NVRAM to the Chassis ID EPROM.
V
CAUTION!
For that reason the front panel and system board must not be replaced
simultaneously! In this case, restoring the system configuration data on
the system board would fail.
When replacing the front panel, the system information like server name and
model, housing type, serial number and manufacturing data are not restored
automatically. So never forget to restore it manually by Chassis ID Prom Tool.

13.1.1 Preliminary steps

"Locating the defective server" on page 51
Ê
"Suspending BitLocker functionality" on page 97
Ê
"Shutting down the server" on page 53
Ê
"Disconnecting the power cord" on page 54
Ê
"Getting access to the component" on page 55
Ê
Ê Remove the system fan module, see section
module" on page 81
376
Upgrade and Maintenance Manual
Hardware: 10 minutes
Software: 5 minutes
"Removing the system fan