Fujitsu PRIMERGY TX1330 M4 Upgrade And Maintenance Manual page 125

Hide thumbs Also See for PRIMERGY TX1330 M4:
Table of Contents

Advertisement

Ê Expand the Cooling Devices group.
Ê Click Start Fan Test
I
For more information on iRMC settings, see the iRMC user guides.
Executing the fan test via ServerView Operations Manager
Ê Open the ServerView Operations Manager and log in.
Ê Under Administration select Server Configuration.
Ê In the hierarchy tree of the Server list tab, select the server to be configured.
Ê In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking GO....
In the left-hand section of the window, the Configuration tab is being
activated.
Ê In the navigation area of the Configuration tab, select Other Settings.
Ê Under Daily Fan Test, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
Ê Click Save Page.
The fan test will be started at the specified time.
Ê After the fan test is complete, restore the time setting to its initial value and
click Save Page.
In case of maintenance done by Fujitsu engineers in Japan:
Executing the fan test via Chassis ID Prom Tool
I
Please follow the instructions provided separately.
TX1330 M4
Upgrade and Maintenance Manual
Basic software procedures
125

Advertisement

Table of Contents
loading

Table of Contents