Appendix A
Pos. Label
Indicator
Global
Error
indicator,
see also
3
"iRMC-
related
status
signals" on
page 461
HDD/SSD
4
activity
indicator
Power-on
5
indicator
460
Status
off
orange
on
flashing
orange
flashing
green
off
green on
flashing
green
slowly
Upgrade and Maintenance Manual
Description
No critical event detected (non CSS
component).
Prefailure event detected (non CSS
component).
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
temperature range
– Defective sensor
– CPU error
– Error detected by server
management software
Data access in progress.
The server is switched off.
– The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
– The server is switched on and
operating normally.
The BMC firmware is starting up after
the server has been connected to the
mains.
TX1330 M4